Skip to content

Stick Welding (SMAW): How It Works, Rods, Settings and Tips

Stick welding (SMAW) explained: how the flux-coated rod works, how to read E6010 and E7018 numbers, polarity, basic technique, and when stick beats MIG.
Source: AISC Shapes Database v16.0Imperial & metric
Stick Welding (SMAW): How It Works, Rods, Settings and Tips

Stick welding, formally shielded metal arc welding (SMAW), joins steel with an electric arc struck between a flux-coated rod and the workpiece. The rod’s core melts to become the filler metal, and its coating burns off to shield the molten pool and leave a layer of slag that you chip away after each pass.

It is the oldest of the common arc processes and still the one most often used outdoors, on site and on rusty or painted structural steel, because it needs no gas bottle and tolerates wind. This guide covers how it works, how to read rod numbers, polarity, basic technique and where stick beats MIG and TIG.

How Stick Welding Works

A stick welder is a constant-current power source with two leads: the electrode holder (the “stinger”) and the work clamp (the ground). When you touch the rod to the work and pull it back slightly, current jumps the gap as an arc. The arc melts the tip of the rod and a small area of the base metal, and the two run together into a weld pool.

The flux coating does three jobs at once. As it burns it gives off gas that pushes air away from the pool, it forms a liquid slag that floats on top of the weld and protects it while it cools, and depending on the rod it adds alloying elements or iron powder. That self-contained shielding is the whole reason stick welding works without a separate gas supply.

Cross-section of a stick weld in progress. A flux-coated electrode with a steel core wire points down at the base metal at a slight drag angle. An arc between the rod tip and the base metal melts a weld pool. Shielding gas from the burning flux surrounds the arc, and a layer of slag covers the solidified weld behind the rod. base metal flux coating core wire shielding gas weld pool slag over finished bead travel
Stick welding: the coating shields the arc and leaves slag over the bead. Rod is dragged, tilted back toward the finished weld. Not to scale.

Stick is one of several arc processes. For the full family, including flux-cored, MIG, TIG and oxy-fuel, see our overview of the types of welding.

What You Need to Stick Weld

  • A constant-current (CC) power source. Transformer machines are AC only or AC/DC; inverter machines are lighter and usually DC. A DC machine runs more rod types smoothly.
  • Electrode holder and work clamp with cables sized for the current.
  • Electrodes in the right classification and diameter for the job.
  • Auto-darkening or fixed-shade helmet, leather gloves, flame-resistant jacket and safety glasses for chipping.
  • Chipping hammer and wire brush to remove slag between passes.
  • Angle grinder to clean mill scale, rust and paint from the joint and to prepare bevels.

OSHA’s construction rule for arc welding and cutting, 29 CFR 1926.351 requires electrode holders designed for arc welding, fully insulated flexible cables rated for the current, and that electrodes be removed from holders left unattended (checked October 2026). Those rules are a good baseline for any shop, not only jobsites.

How to Read a Stick Welding Rod Number

Carbon steel stick electrodes use the AWS A5.1 classification system, printed on every box and on the rod itself near the bare end. In a four-digit code like E7018:

  • E means electrode.
  • 70 is the minimum tensile strength of the weld metal in ksi (70,000 psi).
  • 1 is the welding position: 1 means all positions, 2 means flat and horizontal fillet only.
  • 8 describes the coating type and the current it runs on.

Common Stick Electrodes Compared

RodCoatingCurrentPositionsTypical use
E6010High-cellulose sodiumDCEPAllDeep penetration, root passes on pipe, dirty steel
E6011High-cellulose potassiumAC or DCEPAllLike 6010 but runs on AC machines; farm and repair work
E6013High-titania potassiumAC, DCEP or DCENAllLight sheet and general fabrication; easy arc, shallow penetration
E7018Low-hydrogen potassium, iron powderAC or DCEPAllStructural steel, code work, fill and cap passes
E7024Iron powder, titaniaAC, DCEP or DCENFlat and horizontal filletFast, heavy fillet welds in the flat position

E7018 is the rod most associated with structural steel because its low-hydrogen coating reduces the risk of hydrogen cracking in thicker and higher-strength steel. It has to stay dry to keep that property, which is why jobsites keep it in heated rod ovens. Our 7018 welding rod guide covers storage, amperage and technique for it in detail.

Polarity: DCEP, DCEN and AC

Polarity decides where most of the arc’s heat goes, so the wrong setting gives a poor weld even when the amperage is right.

  • DCEP (DC electrode positive, also called reverse polarity) puts more heat into the work and gives deeper penetration. It is the default for most stick rods, including 6010 and 7018.
  • DCEN (DC electrode negative, straight polarity) puts more heat into the rod, so it melts faster with shallower penetration. It suits thin material with rods rated for it, such as 6013.
  • AC alternates between the two. It is what older buzz-box transformers supply, and it helps with arc blow on magnetized parts. Only use rods rated for AC.

Always check the box: the manufacturer lists the allowed polarity and an amperage range for each rod diameter. Start in the middle of that range on scrap of the same thickness and adjust from there.

Stick Welding Technique: The Basics

Prepare the joint

Stick handles rust and mill scale better than MIG or TIG, but it still welds better on clean steel. Grind the joint area and the spot where the ground clamp goes. Never weld through galvanizing or paint without removing it first; the coating fumes are a health hazard and contaminate the weld. Our guide to welding galvanized steel explains how to strip zinc and ventilate.

Strike and hold the arc

Strike the arc with a quick scratch, like lighting a match, or a light tap. If the rod sticks, twist it free rather than pulling straight back. Once lit, hold an arc length about equal to the diameter of the rod’s core wire. Too long and the arc wanders, spatters and lets air in; too short and the rod sticks or the slag gets trapped.

Angle and travel speed

Use a drag angle, tipping the top of the rod back toward the finished weld by roughly 5 to 15 degrees and pulling it along the joint. Keep the slag behind the puddle; if slag runs ahead of the arc, increase the angle or speed up. Travel at a pace that keeps the bead about two to three times the core wire diameter wide. A bead that is tall and narrow usually means too fast or too cold; one that is wide, flat and undercut at the edges usually means too slow or too hot.

Clean between passes

Chip and brush all slag off before the next pass. Slag left in the joint becomes an inclusion, one of the most common stick welding defects. Inspect the toe of each bead for undercut and the surface for porosity.

Stick vs MIG vs TIG

FactorStick (SMAW)MIG (GMAW)TIG (GTAW)
ShieldingFlux coating on the rodBottled gasBottled inert gas
Outdoors in windGoodPoor without screensPoor
Dirty or rusty steelMost tolerantNeeds clean metalNeeds very clean metal
Thin sheetDifficultGoodBest
SpeedSlow; stop to change rods and chip slagFast, continuous wireSlowest
EquipmentSimplest and most portableWire feeder and gasTorch, gas, often foot pedal
Learning curveModerateEasiestHardest

For shop work on clean steel, MIG is usually faster. For thin stainless or aluminum and appearance welds, TIG wins. Our MIG vs TIG welding comparison goes deeper on those two. Stick earns its place on structural repairs, field erection, farm equipment and anywhere the work goes to the steel rather than the steel coming to the shop.

Stick Welding Structural Steel

Common structural grades such as A36 steel and A992 wide flange beams weld readily with E70-series rods, which is why 7018 shows up so often on structural drawings. Welds on load-carrying members are a different matter from hobby work, though: the weld size, length, electrode and procedure come from the engineer of record, and the welder is normally certified for the position and process. The weld symbols on fabrication drawings spell out what is required.

Any weld that holds up a beam, column, stair, platform or lifting point has to be designed and checked by a licensed structural engineer and made by a qualified welder. Do not size structural welds from a general guide like this one.

Fume and Safety

Stick welding makes more fume than MIG or TIG. In its fact sheet Controlling Hazardous Fume and Gases during Welding, OSHA ranks shielded metal arc second only to flux-cored welding for fume production, and notes that prolonged exposure to manganese fume can cause Parkinson’s-like symptoms (checked October 2026). The same fact sheet recommends:

  • cleaning paint, solvent residue and other coatings off the surface before welding;
  • positioning yourself to keep your head out of the plume, and staying upwind outdoors;
  • using local exhaust ventilation close to the arc where possible;
  • never welding in a confined space without ventilation;
  • using respiratory protection when ventilation and work practices are not enough.

The arc also gives off intense ultraviolet light that burns skin and eyes (“arc eye”) within seconds, so cover all skin and screen off the area from other people. Keep flammables well clear, since slag and spatter travel further than you expect.

Stick Welding FAQ

Is stick welding the same as arc welding?

Stick welding is one type of arc welding. MIG, TIG and flux-cored welding also use an electric arc, but people often say “arc welding” when they mean stick specifically.

Is stick welding hard to learn?

It is harder than MIG at first because you have to feed the rod down as it burns while holding a steady arc length and travel speed. Most people can run a passable flat bead after some practice on scrap; vertical and overhead welds take much longer.

Which rod should a beginner use?

E6013 strikes and runs easily on light material, and E7018 is the rod worth learning for structural steel. On an AC-only machine, E6011 and AC-rated 7018 are the usual choices.

Can you stick weld thin metal?

You can on material down to roughly 1/8 in with small-diameter rods and low current, but it is easy to burn through. Below that, MIG or TIG is the better tool.

Why does my stick rod keep sticking?

Usually the amperage is too low for the rod diameter, the arc length is too short, or low-hydrogen rods have absorbed moisture. Raise the current within the range on the box, hold a slightly longer arc, and keep rods dry.

Reference information only, not engineering advice. Disclaimer.

Look up any steel beam size